131 research outputs found

    A Deep Learning-Based Fully Automated Pipeline for Regurgitant Mitral Valve Anatomy Analysis From 3D Echocardiography

    Get PDF
    Three-dimensional transesophageal echocardiography (3DTEE) is the recommended imaging technique for the assessment of mitral valve (MV) morphology and lesions in case of mitral regurgitation (MR) requiring surgical or transcatheter repair. Such assessment is key to thorough intervention planning and to intraprocedural guidance. However, it requires segmentation from 3DTEE images, which is timeconsuming, operator-dependent, and often merely qualitative. In the present work, a novel workflow to quantify the patient-specific MV geometry from 3DTEE is proposed. The developed approach relies on a 3D multi-decoder residual convolutional neural network (CNN) with a U-Net architecture for multi-class segmentation of MV annulus and leaflets. The CNN was trained and tested on a dataset comprising 55 3DTEE examinations of MR-affected patients. After training, the CNN is embedded into a fully automatic, and hence fully repeatable, pipeline that refines the predicted segmentation, detects MV anatomical landmarks and quantifies MV morphology. The trained 3D CNN achieves an average Dice score of 0.82 +/- 0.06, mean surface distance of 0.43 +/- 0.14 mm and 95% Hausdorff Distance (HD) of 3.57 +/- 1.56 mm before segmentation refinement, outperforming a state-of-the-art baseline residual U-Net architecture, and provides an unprecedented multi-class segmentation of the annulus, anterior and posterior leaflet. The automatic 3D linear morphological measurements of the annulus and leaflets, specifically diameters and lengths, exhibit differences of less than 1.45 mm when compared to ground truth values. These measurements also demonstrate strong overall agreement with analyses conducted by semi-automated commercial software. The whole process requires minimal user interaction and requires approximately 15 seconds

    MitraClip Treatment of Secondary Mitral Regurgitation in Heart Failure with Reduced Ejection Fraction: Lessons and Implications from Trials and Registries

    Get PDF
    Transcatheter mitral valve intervention using the MitraClip system has evolved as a new tool for the treatment of secondary mitral regurgitation (SMR) in patients with heart failure and reduced lef..

    Real-time three dimensional transesophageal echocardiography: technical aspects and clinical applications

    Get PDF
    Real-time three-dimensional transesophageal echocardiography (RT3DTEE) is now commonly used in daily clinical practice. The transesophageal, compared to the transthoracic approach, allows the visualization of the whole spectrum of the mitral valve apparatus and the posterior cardiac structures. Moreover, images obtained by RT 3D TEE provide a unique and complete visualization of the mitral valve prosthetic elements. Indeed, the possibility to visualize guidewires and catheters in cardiac chambers and their relationship with cardiac structures during percutaneous transcatheter procedures reduces the time of radiation exposure and simplifies the approach becoming the reference method for monitoring. This review aims to underline the potential clinical applications and the advantages of RT3DTEE compared to other methods

    Complicated Bi-Pella Support: Acute Mitral Regurgitation and Bailout MitraClip Repair

    Get PDF
    During the last decades, the use of mechanical circulatory support devices (MCS) has increased exponentially. In this scenario, a fully percutaneous approach to biventricular cardiogenic shock has ..

    Relation between left ventricular contractile reserve during low dose dobutamine echocardiography and plasma concentrations of natriuretic peptides

    Get PDF
    BACKGROUND: In ischaemic cardiomyopathy, raised plasma concentrations of natriuretic peptides are associated with a poor long term prognosis, while the presence of contractile reserve is a favourable sign. OBJECTIVE: To assess the relation between plasma natriuretic peptides and contractile reserve. DESIGN: Prospective observational study. SETTING: Tertiary referral centre. PATIENTS: 66 consecutive patients undergoing low dose dobutamine stress echocardiography to evaluate contractile reserve in regions with contractile dysfunction at rest, divided into two groups: group 1, 31 patients with ischaemic cardiomyopathy (left ventricular ejection fraction < or = 40%) and heart failure symptoms; group 2, 35 patients with normal left ventricular function. MAIN OUTCOME MEASURES: Plasma atrial natriuretic peptide (ANP) and brain natriuretic peptide (BNP), measured using immunoradiometric assays. Contractile reserve was defined as an improvement in segmental wall motion score during infusion of low dose dobutamine. RESULTS: Plasma ANP and BNP concentrations were higher in group 1 than in group 2 (mean (SD): ANP, 17.8 (32.8) v 7.2 (9.7), p < 0.005; BNP, 24.4 (69.0) v 5.0 (14.3) pmol/l, respectively; p < 0.001). In group 1, the presence of contractile reserve was inversely related to ANP and BNP levels; however, patients with contractile reserv

    Left atrial appendage occlusion in the absence of intraprocedural product specialist monitoring: is it time to proceed alone? Results from a multicenter real-world experience

    Get PDF
    BackgroundPercutaneous left atrial appendage occlusion (LAAO) presents many technical complex features, and it is often performed under the intraprocedural surveillance of a product specialist (PS). Our aim is to assess whether LAAO is equally safe and effective when performed in high-volume centers without PS support.MethodsIntraprocedural results and long-term outcome were retrospectively assessed in 247 patients who underwent LAAO without intraprocedural PS monitoring between January 2013 and January 2022 at three different hospitals. This cohort was then matched to a population who underwent LAAO with PS surveillance. The primary end point was all-cause mortality at 1 year. The secondary end point was a composite of cardiovascular mortality plus nonfatal ischemic stroke occurrence at 1 year.ResultsOf the 247 study patients, procedural success was achieved in 243 patients (98.4%), with only 1 (0.4%) intraprocedural death. After matching, we did not identify any significant difference between the two groups in terms of procedural time (70 ± 19 min vs. 81 ± 30 min, p = 0.106), procedural success (98.4% vs. 96.7%, p = 0.242), and procedure-related ischemic stroke (0.8% vs. 1.2%, p = 0.653). Compared to the matched cohort, a significant higher dosage of contrast was used during procedures without specialist supervision (98 ± 19 vs. 43 ± 21, p &lt; 0.001), but this was not associated with a higher postprocedural acute kidney injury occurrence (0.8% vs. 0.4%, p = 0.56). At 1 year, the primary and the secondary endpoints occurred in 21 (9%) and 11 (4%) of our cohort, respectively. Kaplan–Meier curves showed no significant difference in both primary (p = 0.85) and secondary (p = 0.74) endpoint occurrence according to intraprocedural PS monitoring.ConclusionsOur results show that LAAO, despite the absence of intraprocedural PS monitoring, remains a long-term safe and effective procedure, when performed in high-volume centers

    Hand-held echocardiography: added value in clinical cardiological assessment

    Get PDF
    BACKGROUND: The ultrasonic industry has recently produced echocardiographic Hand Held Devices (miniaturized, compact and battery-equipped echocardiographic systems). Their potential usefulness has been successfully assessed in a wide range of clinical conditions. The aim of the study was to verify if the routine use of a basic model of echocardiographic Hand Held Device (HHD) could be an important diagnostic tool during outpatient cardiologic consulting or in non-cardiologic hospital sections. METHODS: 87 consecutive patients were included in this study; they underwent routine physical examination, resting ECG and echocardiographic evaluation using a basic model of HHD performed by trained echocardiographists; the cardiologist, whenever possible, formulated a diagnosis. The percentage of subjects in whom the findings were judged reasonably adequate for final diagnostic and therapeutic conclusions was used to quantify the "conclusiveness" of HHD evaluation. Successively, all patients underwent a second echocardiographic evaluation, by an examiner with similar echocardiographic experience, performed using a Standard Echo Device (SED). The agreement between the first and the second echocardiographic exam was also assessed. RESULTS: Mean examination time was 6.7 ± 1.5 min. using HHD vs. 13.6 ± 2.4 min. using SED. The echocardiographic examination performed using HHD was considered satisfactory in 74/87 patients (85.1% conclusiveness). Among the 74 patients for whom the examination was conclusive, the diagnosis was concordant with that obtained with the SED examination in 62 cases (83.8% agreement). CONCLUSION: HHD may generally allow a reliable cardiologic basic evaluation of outpatient or subjects admitted to non-cardiologic sections, more specifically in particular subgroups of patients, with a gain in terms of time, shortening patient waiting lists and reducing healthy costs
    • …
    corecore